F4E4 — Humidity Thermistor Fault
The humidity thermistor is reading open or shorted, or its wiring is bad. Sensor-based cook modes will fail; the unit usually still runs manually.
- Keep using it?
- Yes, with caution
- DIY difficulty
- Technician
- Verified against
- producthelp.whirlpool.com ↗ Page last updated 2026-11-21
How to fix it
- Power down at the breaker for 1 minute and retest.
- If the code keeps coming back, stop using the microwave and contact the manufacturer's service line or a qualified appliance technician.
- Do not open the microwave cabinet. The high-voltage capacitor inside can hold a lethal charge even when the microwave is unplugged; testing or replacing internal parts is a job for a qualified technician.
Why it happens
Typical signs: F4E4 on the display · Sensor Cook / Steam / Reheat fails immediately · Code returns even after a full power cycle
- Failed humidity thermistor Resistance drifts open or shorts — most common cause.
- Damaged thermistor wiring Wires routed through hinge or vent area can chafe.
- Loose connector at the control board Check both ends of the harness.
More Whirlpool microwave codes
Frequently asked questions
What does the F4E4 code mean on a Whirlpool microwave?
The humidity thermistor is reading open or shorted, or its wiring is bad. Sensor-based cook modes will fail; the unit usually still runs manually.
What causes the F4E4 code on a Whirlpool microwave?
Failed humidity thermistor: Resistance drifts open or shorts — most common cause. Damaged thermistor wiring: Wires routed through hinge or vent area can chafe. Loose connector at the control board: Check both ends of the harness.
Is it safe to keep using a Whirlpool microwave with a F4E4 error?
Yes, with caution. This is rated a moderate-severity fault.
How do I fix F4E4 on a Whirlpool microwave?
Power down at the breaker for 1 minute and retest. If the code keeps coming back, stop using the microwave and contact the manufacturer's service line or a qualified appliance technician. Do not open the microwave cabinet. The high-voltage capacitor inside can hold a lethal charge even when the microwave is unplugged; testing or replacing internal parts is a job for a qualified technician.
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: producthelp.whirlpool.com.