Whirlpool · Dryer Serious

F3E3 — Inlet Thermistor Error

Whirlpool lists F3E3 as an inlet thermistor error: a problem with the temperature sensor on the heater housing. Its first fix is a one-minute power reset at the breaker.

Keep using it?
Limited use only
DIY difficulty
Moderate
Verified against
producthelp.whirlpool.com ↗ Whirlpool Product Help: F3 E3 - Error Code - Dryer Page last updated 2026-11-21

How to fix it

  1. Turn the dryer off at the circuit breaker(s) for one minute, turn it back on, start a Timed Dry cycle and watch it for a minute to see whether the code returns (Whirlpool's first step).
  2. Unplug the dryer and access the heater housing per the tech sheet (back panel on most models).
  3. Locate the inlet thermistor on the heater housing.
  4. Disconnect it and measure its resistance; compare with the value on the tech sheet for your model.
  5. Inspect the harness for melt damage from the heater.
  6. Replace the inlet thermistor; if the code returns, replace the main control board.

Why it happens

Typical signs: F3E3 on display · No heat or heat shuts off early · Cycle aborts shortly after start · Clothes damp at end of cycle

  • Failed inlet thermistor Sensor element open or shorted.
  • Burnt harness near heater Heat damage to the wires running near the heating element housing.
  • Bad main control input Failed thermistor input circuit on the main control board.

Parts you may need

If diagnosis points to a failed part, these are the common replacements. As an Amazon Associate we earn from qualifying purchases.

More Whirlpool dryer codes

All Whirlpool codes → All dryer codes →

Frequently asked questions

What does the F3E3 code mean on a Whirlpool dryer?

Whirlpool lists F3E3 as an inlet thermistor error: a problem with the temperature sensor on the heater housing. Its first fix is a one-minute power reset at the breaker.

What causes the F3E3 code on a Whirlpool dryer?

Failed inlet thermistor: Sensor element open or shorted. Burnt harness near heater: Heat damage to the wires running near the heating element housing. Bad main control input: Failed thermistor input circuit on the main control board.

Is it safe to keep using a Whirlpool dryer with a F3E3 error?

Limited use only. This is rated a serious-severity fault.

How do I fix F3E3 on a Whirlpool dryer?

Turn the dryer off at the circuit breaker(s) for one minute, turn it back on, start a Timed Dry cycle and watch it for a minute to see whether the code returns (Whirlpool's first step). Unplug the dryer and access the heater housing per the tech sheet (back panel on most models). Locate the inlet thermistor on the heater housing.

Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: producthelp.whirlpool.com.