F-4 — Humidity / steam sensor fault
The humidity (steam) sensor used for Auto Cook and Sensor Reheat is out of range, open, or shorted. Sensor-based cooking is disabled until repaired.
- Keep using it?
- Limited use only
- DIY difficulty
- Technician
- Verified against
- lg.com ↗ Page last updated 2026-11-21
How to fix it
- Wipe grease off the vents around the top of the microwave with a damp cloth.
- Unplug the microwave (or switch it off at the breaker) for 60 seconds, then plug it back in and try a short cook cycle.
- If the code comes back, stop using the microwave and contact LG service or a qualified appliance technician.
- Do not open the microwave cabinet. The high-voltage capacitor inside can hold a lethal charge even when the microwave is unplugged; internal parts are for a qualified technician.
Why it happens
Typical signs: F-4 on display · Sensor cook cycles end prematurely or refuse to start · Manual time-cook still works
- Failed humidity / gas sensor The sensor element has aged or been fouled by smoke and grease.
- Disconnected sensor harness Plug at the sensor or PCB has worked loose.
- Blocked sensor vent Grease film over the sensor port prevents steam from reaching the element.
- Main control board failure Bias circuit for the sensor on the PCB is bad.
More LG microwave codes
Frequently asked questions
What does the F-4 code mean on a LG microwave?
The humidity (steam) sensor used for Auto Cook and Sensor Reheat is out of range, open, or shorted. Sensor-based cooking is disabled until repaired.
What causes the F-4 code on a LG microwave?
Failed humidity / gas sensor: The sensor element has aged or been fouled by smoke and grease. Disconnected sensor harness: Plug at the sensor or PCB has worked loose. Blocked sensor vent: Grease film over the sensor port prevents steam from reaching the element.
Is it safe to keep using a LG microwave with a F-4 error?
Limited use only. This is rated a serious-severity fault.
How do I fix F-4 on a LG microwave?
Wipe grease off the vents around the top of the microwave with a damp cloth. Unplug the microwave (or switch it off at the breaker) for 60 seconds, then plug it back in and try a short cook cycle. If the code comes back, stop using the microwave and contact LG service or a qualified appliance technician.
Always unplug an appliance before servicing it. This guide is for informational purposes and is not a substitute for a qualified technician. Verified against manufacturer documentation: lg.com.